| Portable | Non Portable |
|---|---|
| Brand | Fraxco2 |
| Wavelength | 10600nm |
| Laser Device | 70W USA Coherent Laser |
| Handle | Scan Probe; Cutting Probe*3; Vaginal Probe*3 |
| Laser Arm | Korea Import Articulated 7 Joint Arm |
| Working Mode | Fractional , Surgical , Vaginal (Optional) |
| Cooling System | 7 Big Power Smart Fans Self Contained, Closed Cycl |
| Scan Mode | Order Mode, Disorder Mode, Midsplit Mode |
| Scan Size | 0.4X0.4mm -20X20mm |
| Scan Pattern | 7 Dfferent Kind of Shapes |
| Duration | 0.1-10ms |
| Distance | 0.1mm-2.6mm |
| Treatment | Wrinkle Removal/Vaginal Treatment/Skin Rejuvenatio |
| Vaginal Handle | 180 /360 Degree |
| Origin | China |
FC100 - Co2 Fractional Laser
| Model Name | Fraxco2 _ FC100 _ Co2 fractional laser |
|---|---|
| Laser System | Fractional / Normal / Gynae / Vulvae |
| Power | 50w / 70w Import from USA |
| Handle | Smart Scan head |
| Motor | German photoelectric diffuse reflection nano soft magnetic alloy material sensor |
| Light Guide Arm | 7-section light guide arm from Korea |
| Voltage | 110V/220V 50HZ/60HZ |
| Scanning Launch Model | positive, reverse, out |
| Function | Skin rejuvenation, vaginal rejuvenation, scar removal |
| Spot Distance | 0.1mm-2.6mm(adjustable) |
| Scan Times | 1-20 times |
| Stand-by Working | Continuously for more than 18 hours |
| Scan Size | Up to 20x20mm |
| Scan Shapes | Square, Rectangle, Circle, Triangle, Rhombus, Ellipse, Line |
Co2 Fractional Laser - Under a certain energy density, the laser beam can penetrate through the epidermis and enter the dermis. Since the absorption is relatively good, the thermal energy generated by the tissue in the part where the laser passes through absorbing the laser energy will lead to columnar thermal degeneration of the part. Along with this process, all layers in the skin are rebuilt: a certain degree of exfoliation of the epidermis, new collagen from the dermis, etc.
Co2 Fractional Laser - Laser technology based on this principle is also known as lattice laser and pixel laser. It is a new technology that transforms the emission mode of traditional laser into pixel mode. Compared with traditional lasers, pixel lasers change the emission mode of light, and control the originally small laser beams through a scanner and a space lens matrix into even smaller laser beams, which act on the skin to generate hundreds of thousands of microporous hot zones.
Co2 Fractional Laser - Completely different from the previous traumatic and non-ablative skin rejuvenation, the establishment and further clinical application of this new technology allow us to avoid the problem of long recovery time and low safety in traumatic treatment, and overcome the weak point of poor technical efficacy in non-ablative skin rejuvenation, establishing a safe and efficient means of skin rejuvenation.
The light guide arm and the machine utilize aviation butt plugs. Crafted from high-quality metal alloys on the exterior, it contains 24 gold-plated welding pins inside. The connection is stable, reliable, easy to plug/unplug, and features dustproof and antifouling designs.
The connecting line adopts high-end customized cores featuring strong anti-aging, low energy consumption, and high-current load capacity. The wire sheath provides outstanding shielding, anti-interference, insulation, wear resistance, and flexibility.
Made of high-strength specific austenitic stainless steel material. Its novel and streamlined design optimizes the viewing angle, making target adjustments more intuitive.
The air nozzle blows vertically and at 45-degree angles to sweep smoke away thoroughly, protecting the optical lens from pollution. It also provides comfort and pain relief for clients during the treatment process.
Prevents polarization risks from long-term dragging, which can lead to poor light output and operation fatigue.
Features 360° rotation without dead angles. Equipped with internal gold-plated lenses to support excellent refraction and reflection, maximizing uniform light output without energy loss.
Assists in smooth operation, preventing polarization and improving balance control.
- FraxCO2® Technology: Deepest penetration, lowest energy, reduces patient discomfort and thermal damage.
- FraxDeep™ & FraxShape™ Technology: Combines focused energy strips and AI scanning head to achieve deep penetration and precise pattern construction.
- 360° Vaginal Tightening Technology: Gold-plated treatment head reduces energy loss and effectively shortens treatment time.
- Multiple Handpieces: Offers a full range of technologies and applications for different skin issues.
- 70W Coherent Laser (USA): Stable performance, unlimited lifespan, high reliability, high peak power, short pulse rise time, and high pulse modulation frequency.
- Multiple Operating Modes: Fractional mode, surgical mode, vaginal mode (optional).
- Scanning Modes and Patterns: Ordered mode, disordered mode, middle separation mode; 7 different shapes (circle, square, rectangle, hexagon, triangle, line, oval).
- Self-Contained Closed-Loop Cooling System: Air cooling with 7 high-power intelligent fans.
- Vaginal and Pelvic Floor Health: Addresses urinary incontinence, cervical ectropion, vaginal odor, and enhances sexual life.
- Internal Vaginal Treatment: Promotes collagen regeneration, improves vaginal tightness, and increases vaginal sensitivity.
- External Vulvar Treatment: Reduces vulvar redness and swelling, enhances vulvar aesthetics, and lowers the risk of genital tumors.
- Ergonomic Handpiece: Lightweight, comfortable grip, and flexible operation.